Программа Сервисный Центр
Сортировать новости по: дате новости | популярности | посещаемости | комментариям | алфавиту
SCSI-II External Hi D-Sub (Differential)

50 PIN HI-DENSITY D-SUB FEMALE (at the controller & devices).
50 PIN HI-DENSITY D-SUB MALE (To the cable).

50 PIN HI-DENSITY D-SUB FEMALE at the controller & devices.
50 PIN HI-DENSITY D-SUB MALE at the cable.


Pin Name Dir Description
01 GND --- Ground
02 +DB0 <-> +Data Bus 0
03 +DB1 <-> +Data Bus 1
04 +DB2 <-> +Data Bus 2
05 +DB3 <-> +Data Bus 3
06 +DB4 <-> +Data Bus 4
07 +DB5 <-> +Data Bus 5
08 +DB6 <-> +Data Bus 6
09 +DB7 <-> +Data Bus 7
10 +DBP <-> +Data Bus Parity (odd Parity)
11 DIFFSENS ? ???
12 res - Reserved
13 TERMPWR <-> Termination Power
14 res - Reserved
15 +ATN <-- +Attention
16 GND --- Ground
17 +BSY <-> +Bus is busy
18 +ACK <-- +Acknowledge
19 +RST <-> +Reset
20 +MSG --> +Message
21 +SEL <-> +Select
22 +C/D --> +Control or Data
23 +REQ --> +Request
24 +I/O --> +In/Out
25 GND --- Ground
26 GND --- Ground
27 -DB0 <-> -Data Bus 0
28 -DB1 <-> -Data Bus 1
29 -DB2 <-> -Data Bus 2
30 -DB3 <-> -Data Bus 3
31 -DB4 <-> -Data Bus 4
32 -DB5 <-> -Data Bus 5
33 -DB6 <-> -Data Bus 6
34 -DB7 <-> -Data Bus Parity7
35 -DBP <-> -Data Bus Parity (odd Parity)
36 GND --- Ground
37 res - Reserved
38 TERMPWR <-> Termination Power
39 res - Reserved
40 -ATN <-- -Attention
41 GND --- Ground
42 -BSY <-> -Bus is busy
43 -ACK <-- -Acknowledge
44 -RST <-> -Reset
45 -MSG --> -Message
46 -SEL <-> -Select
47 -C/D --> -Control or Data
48 -REQ --> -Request
49 -I/O --> -In/Out
50 GND --- Ground

Note: Direction is Device relative Bus (other Devices).

 
SCSI-III External Hi D-Sub (Differential)

68 PIN HI-DENSITY D-SUB FEMALE (at the controller & devices).
68 PIN HI-DENSITY D-SUB MALE (To the cable).

68 PIN HI-DENSITY D-SUB FEMALE at the controller & devices.
68 PIN HI-DENSITY D-SUB MALE at the cable.


Pin Name Dir Description
1 +DB12 <-> Data Bus 12
2 +DB13 <-> Data Bus 13
3 +DB14 <-> Data Bus 14
4 +DB15 <-> Data Bus 15
5 +DPB1 <-> Data Parity (odd Parity)
6 GND --- Ground
7 +DB0 <-> Data Bus 0
8 +DB1 <-> Data Bus 1
9 +DB2 <-> Data Bus 2
10 +DB3 <-> Data Bus 3
11 +DB4 <-> Data Bus 4
12 +DB5 <-> Data Bus 5
13 +DB6 <-> Data Bus 6
14 +DB7 <-> Data Bus 7
15 +DPB <-> Data Parity (odd Parity)
16 DIFFSENSE ? Diff Sense?
17 TERMPWR <-> Termination Power
18 TERMPWR <-> Termination Power
19 res --- reserved
20 +ATN <-- Attention
21 GND --- Ground
22 +BSY <-> Busy
23 +ACK <-- Acknowledge
24 +RST <-> Reset
25 +MSG --> Message
26 +SEL <-> Select
27 +C/D --> Control/Data
28 +REQ --> Request
29 +I/O --> Input/Output
30 GND --- Ground
31 +DB8 <-> Data Bus 8
32 +DB9 <-> Data Bus 9
33 +DB10 <-> Data Bus 10
34 +DB11 <-> Data Bus 11
35 -DB12 <-> Data Bus 12
36 -DB13 <-> Data Bus 13
37 -DB14 <-> Data Bus 14
38 -DB15 <-> Data Bus 15
39 -DPB1 <-> Data Parity (odd Parity)
40 GND --- Ground
41 -DB0 <-> Data Bus 0
42 -DB1 <-> Data Bus 1
43 -DB2 <-> Data Bus 2
44 -DB3 <-> Data Bus 3
45 -DB4 <-> Data Bus 4
46 -DB5 <-> Data Bus 5
47 -DB6 <-> Data Bus 6
48 -DB7 <-> Data Bus 7
49 -DPB <-> Data Parity (odd Parity)
50 GND --- Ground
51 TERMPWR <-> Termination Power
52 TERMPWR <-> Termination Power
53 res --- reserved
54 -ATN <-- Attention
55 GND --- Ground
56 -BSY <-> Busy
57 -ACK <-- Acknowledge
58 -RST <-> Reset
59 -MSG --> Message
60 -SEL <-> Select
61 -C/D --> Control/Data
62 -REQ --> Request
63 -I/O --> Input/Output
64 GND --- Ground
65 -DB8 <-> Data Bus 8
66 -DB9 <-> Data Bus 9
67 -DB10 <-> Data Bus 10
68 -DB11 <-> Data Bus 11

Note: Direction is Device relative Bus (other Devices).

 
SCSI Internal (Differential)

50 PIN IDC MALE (at the controller & harddisk.)
50 PIN IDC FEMALE (at the cable.)

50 PIN IDC MALE at the controller & harddisk.
50 PIN IDC FEMALE at the cable.

Pin Name Dir Description
01 GND --- Ground
02 GND --- Ground
03 +DB0 <-> +Data Bus 0
04 -DB0 <-> -Data Bus 0
05 +DB1 <-> +Data Bus 1
06 -DB1 <-> -Data Bus 1
07 +DB2 <-> +Data Bus 2
08 -DB2 <-> -Data Bus 2
09 +DB3 <-> +Data Bus 3
10 -DB3 <-> -Data Bus 3
11 +DB4 <-> +Data Bus 4
12 -DB4 <-> -Data Bus 4
13 +DB5 <-> +Data Bus 5
14 -DB5 <-> -Data Bus 5
15 +DB6 <-> +Data Bus 6
16 -DB6 <-> -Data Bus 6
17 +DB7 <-> +Data Bus 7
18 -DB7 <-> -Data Bus Parity7
19 +DBP <-> +Data Bus Parity (odd Parity)
20 -DBP <-> -Data Bus Parity (odd Parity)
21 DIFFSENS ? ???
22 GND --- Ground
23 res - Reserved
24 res - Reserved
25 TERMPWR <-> Termination Power
26 TERMPWR <-> Termination Power
27 res - Reserved
28 res - Reserved
29 +ATN <-- +Attention
30 -ATN <-- -Attention
31 GND --- Ground
32 GND --- Ground
33 +BSY <-> +Bus is busy
34 -BSY <-> -Bus is busy
35 +ACK <-- +Acknowledge
36 -ACK <-- -Acknowledge
37 +RST <-> +Reset
38 -RST <-> -Reset
39 +MSG --> +Message
40 -MSG --> -Message
41 +SEL <-> +Select
42 -SEL <-> -Select
43 http://www.bdn.odessa.ua/HWB/td> --> +Control or Data
44 http://www.bdn.odessa.ua/HWB/td> --> -Control or Data
45 +REQ --> +Request
46 -REQ --> -Request
47 http://www.bdn.odessa.ua/HWB/td> --> +In/Out
48 http://www.bdn.odessa.ua/HWB/td> --> -In/Out
49 GND --- Ground
50 GND --- Ground

Note: Direction is Device relative Bus (other Devices).

 
SCSI External Centronics 50 (Differential)

50 PIN CENTRONICS FEMALE (at the controller & devices)
50 PIN CENTRONICS MALE (at the cable)

50 PIN CENTRONICS FEMALE at the controller & devices.
50 PIN CENTRONICS MALE at the cable.


Pin Name Dir Description
01 GND --- Ground
02 +DB0 <-> +Data Bus 0
03 +DB1 <-> +Data Bus 1
04 +DB2 <-> +Data Bus 2
05 +DB3 <-> +Data Bus 3
06 +DB4 <-> +Data Bus 4
07 +DB5 <-> +Data Bus 5
08 +DB6 <-> +Data Bus 6
09 +DB7 <-> +Data Bus 7
10 +DBP <-> +Data Bus Parity (odd Parity)
11 DIFFSENS ? ???
12 res - Reserved
13 TERMPWR <-> Termination Power
14 res - Reserved
15 +ATN <-- +Attention
16 GND --- Ground
17 +BSY <-> +Bus is busy
18 +ACK <-- +Acknowledge
19 +RST <-> +Reset
20 +MSG --> +Message
21 +SEL <-> +Select
22 +C/D --> +Control or Data
23 +REQ --> +Request
24 +I/O --> +In/Out
25 GND --- Ground
26 GND --- Ground
27 -DB0 <-> -Data Bus 0
28 -DB1 <-> -Data Bus 1
29 -DB2 <-> -Data Bus 2
30 -DB3 <-> -Data Bus 3
31 -DB4 <-> -Data Bus 4
32 -DB5 <-> -Data Bus 5
33 -DB6 <-> -Data Bus 6
34 -DB7 <-> -Data Bus Parity7
35 -DBP <-> -Data Bus Parity (odd Parity)
36 GND --- Ground
37 res - Reserved
38 TERMPWR <-> Termination Power
39 res - Reserved
40 -ATN <-- -Attention
41 GND --- Ground
42 -BSY <-> -Bus is busy
43 -ACK <-- -Acknowledge
44 -RST <-> -Reset
45 -MSG --> -Message
46 -SEL <-> -Select
47 -C/D --> -Control or Data
48 -REQ --> -Request
49 -I/O --> -In/Out
50 GND --- Ground

Note: Direction is Device relative Bus (other Devices).

 
 
 
Обратная связь

Наши партнеры

 

Опросы

Есть ли справедливость в жизни?
Конечно есть, уверен!
Вроде как должна быть, но...
Затрудняюсь ответить...
Какая справедливость? О чем Вы?
Эх.., нет правды на свете!

 

Облако тегов

Требуется для просмотраFlash Player 9 или выше.

Показать все теги
 

Календарь публикаций

«    Ноябрь 2017    »
ПнВтСрЧтПтСбВс
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
 
 

Архив новостей

Сентябрь 2017 (4)
Август 2017 (36)
Июль 2017 (32)
Июнь 2017 (42)
Май 2017 (45)
Апрель 2017 (47)
 
Наверх Сервисные мануалы Даташиты Ремонт LCD, ЖК телевизоров LG Samsung Скрипт программы "Сервисный центр"